Artificial intelligence-enhanced 3D gait analysis with a single consumer-grade camera

Page view(s)
1
Checked on Aug 26, 2025
Artificial intelligence-enhanced 3D gait analysis with a single consumer-grade camera
Title:
Artificial intelligence-enhanced 3D gait analysis with a single consumer-grade camera
Journal Title:
Journal of Biomechanics
Keywords:
Publication Date:
02 May 2025
Citation:
Guo, L., Chang, R., Wang, J., Narayanan, A., Qian, P., Leong, M. C., Kundu, P. P., Senthilkumar, S., Garlapati, S. C., Yong, E. C. K., & Pahwa, R. S. (2025). Artificial intelligence-enhanced 3D gait analysis with a single consumer-grade camera. Journal of Biomechanics, 187, 112738. https://doi.org/10.1016/j.jbiomech.2025.112738
Abstract:
Gait analysis is crucial for diagnosing and monitoring various healthcare conditions, but traditional marker-based motion capture (MoCap) systems require expensive equipment, extensive setup, and trained personnel, limiting their accessibility in clinical and home settings. Markerless systems reduce setup complexity but often require multiple cameras, fixed calibration, and are not designed for widespread clinical adoption. This study introduces 3DGait, an artificial intelligence-enhanced markerless 3-Dimensional gait analysis system that operates with a single consumer-grade depth camera, providing a streamlined, accessible alternative. The system integrates advanced machine learning algorithms to produce 49 angular, spatial, and temporal gait biomarkers commonly used in mobility analysis. We validated 3DGait against a marker-based MoCap (OptiTrack) using 16 trials from 8 healthy adults performing the Timed Up and Go (TUG) test. The system achieved an overall average mean absolute error (MAE) of 2.3◦, with all MAE under 5.2◦, and a Pearson’s correlation coefficient (PCC) of 0.75 for angular biomarkers. All spatiotemporal biomarkers had errors no greater than 15 %. Temporal biomarkers (excluding TUG time) had errors under 0.03 s, corresponding to one video frame at 30 frames per second. These results demonstrate that 3DGait provides clinically acceptable gait metrics relative to marker-based MoCap, while eliminating the need for markers, calibration, or fixed camera placement. 3DGait’s accessible, non-invasive and single camera design makes it practical for use in non-specialist clinics and home settings, supporting patient monitoring and chronic disease management. Future research will focus on validating 3DGait with diverse populations, including individuals with gait abnormalities, to broaden its clinical applications.
License type:
Attribution-NonCommercial-NoDerivatives 4.0 International (CC BY-NC-ND 4.0)
Funding Info:
This research / project is supported by the Agency for Science, Technology and Research - Innovation and Enterprise Office (IEO) Decentralised GAP
Grant Reference no. : I23D1AG090
Description:
ISSN:
0021-9290
Files uploaded:


File Size Format Action
manuscript-combined-all.pdf 898.73 KB PDF Open
supplementary-material.pdf 649.52 KB PDF Open