State-of-the-Art Imaging and Localization Assessment in Post-Operative Deep Brain Stimulation for Parkinson’s Disease: A Review

Page view(s)
0
Checked on
State-of-the-Art Imaging and Localization Assessment in Post-Operative Deep Brain Stimulation for Parkinson’s Disease: A Review
Title:
State-of-the-Art Imaging and Localization Assessment in Post-Operative Deep Brain Stimulation for Parkinson’s Disease: A Review
Journal Title:
Stereotactic and Functional Neurosurgery
Keywords:
Publication Date:
11 June 2026
Citation:
Susanto, K. T., Premchand, B., Wan, K. R., Yu, W.-Y., Oh, H. P., Chan, V. E. Y., Misbaah, F., & So, R. Q. (2026). State-of-the-Art Imaging and Localization Assessment in Post-Operative Deep Brain Stimulation for Parkinson’s Disease: A Review. Stereotactic and Functional Neurosurgery, 1–22. Portico. https://doi.org/10.1159/000553009
Abstract:
Deep brain stimulation (DBS) is an established therapy for Parkinson’s disease (PD), dependent on precise electrode placement relative to intended anatomical and functional targets. Post-operative imaging, primarily magnetic resonance imaging (MRI) and computed tomography (CT), is essential for verifying lead position, assessing surgical accuracy, and guiding stimulation programming. Most centers perform imaging within the first week after surgery, typically using CT or MRI–CT fusion to confirm electrode location and detect complications. CT offers submillimeter resolution (slice thickness 0.5-1.25 mm; voxel ~0.5 mm) for clear electrode visualization, while MRI (particularly T1-MPRAGE, T2-FLAIR, and GRE sequences) provides superior anatomical contrast and artifact characterization. Registration between pre- and post-operative scans remains the predominant localization technique, though automated pipelines such as Lead-DBS, Brainlab Elements™, SureTune4™ now achieve consistent precision within ±0.5–1.5 mm across platforms. This review summarizes current post-operative imaging strategies and quantitative localization techniques in DBS for PD. It discusses the advantages and limitations of each modality and outlines future directions in automation, multimodal integration, and personalized imaging pipelines for improving the accuracy, reproducibility, and clinical utility of post-operative DBS assessment.
License type:
Attribution-NonCommercial 4.0 International (CC BY-NC 4.0)
Funding Info:
There was no specific funding for the research done
Description:
The final, published version of this article is available at https://www.karger.com/?doi=10.1159/000553009
ISSN:
1011-6125
1423-0372
Files uploaded:

File Size Format Action
001-published-sfn-paper.pdf 2.85 MB PDF Open