Traceable Site-VSWR Measurements for Validating Anechoic Chamber

Page view(s)
48
Checked on Mar 04, 2025
Traceable Site-VSWR Measurements for Validating Anechoic Chamber
Title:
Traceable Site-VSWR Measurements for Validating Anechoic Chamber
Journal Title:
2018 Conference on Precision Electromagnetic Measurements (CPEM 2018)
Publication Date:
08 July 2018
Citation:
Y. S. Meng, J. Deng and Y. Shan, "Traceable Site-VSWR Measurements for Validating Anechoic Chamber," 2018 Conference on Precision Electromagnetic Measurements (CPEM 2018), Paris, 2018, pp. 1-2. doi: 10.1109/CPEM.2018.8500947
Abstract:
This paper presents recent works on traceable site-VSWR (Voltage Standing Wave Ratio) measurements for validating RF semi-anechoic chamber in 1 GHz – 18 GHz, in accordance with CISPR (International Special Committee on Radio Interference) 16-1-4 technical standard. In this work, site imperfection which is an important contributor for radiated emission measurement uncertainties, have been accurately characterized and discussed using different antenna height and polarization.
License type:
PublisherCopyrights
Funding Info:
Description:
© 2018 IEEE. Personal use of this material is permitted. Permission from IEEE must be obtained for all other uses, in any current or future media, including reprinting/republishing this material for advertising or promotional purposes, creating new collective works, for resale or redistribution to servers or lists, or reuse of any copyrighted component of this work in other works.
ISSN:
2160-0171
0589-1485
ISBN:
978-1-5386-0974-3
978-1-5386-0973-6
978-1-5386-2130-1
Files uploaded:
File Size Format Action
There are no attached files.